Adding 0.5% graphene to grease lowers its peak operating temperature by about 30%

Researchers at Ontario Tech University in Canada have used graphene nanoplatelets to cool and protect a commercial lithium grease. They also built a machine learning framework that predicts how such greases heat up and wear over time.

The team mixed graphene nanoplatelets, supplied by Nova Graphene, into a commercial lithium grease at concentrations of 0, 0.25, 0.5, 0.75, 1 and 2 wt%. The platelets are 50 nm to 5 µm across and under 1.7 nm thick. They tested each formulation ten times in a block-on-ring setup, with an aluminum block pressed against a rotating steel ring (1,000 rpm, 4.9 N load, 360 seconds). Temperature was recorded with an infrared camera.

 

The plain grease heated up to around 90°C by the end of the test. With 0.5 wt% graphene, the peak was around 61-62°C, roughly 30% lower. The benefit was not linear: at 1 and 2 wt%, peak temperatures rose slightly again. The researchers say clustering of the graphene or changes in the grease structure are possible explanations, but they did not confirm this.

Wear followed a similar pattern. The model-predicted wear scar area fell from about 47.8 mm² for the plain grease to 30-32 mm² for graphene concentrations of 0.25-0.75 wt%, a reduction of about 35%. Predicted wear depth dropped from about 87 µm to 68-71 µm, with the lowest value near 0.5 wt%. The team notes that these wear figures are model predictions, supported by their earlier experimental work on graphene greases, rather than a new statistical test.

The framework first predicts the full temperature curve from the graphene concentration and load, then uses it to estimate wear, friction and the lubrication regime as the grease film thins out. On held-out data, it reached coefficients of determination of 0.97 for temperature, 0.95 for wear scar area, 0.94 for wear depth and 0.92 for friction. The team expanded their small dataset statistically from the measured averages and spreads, so those scores reflect the limited conditions tested: one grease, one graphene type, a narrow range of loads and speeds. They plan to test wider conditions, other grease types and eventually real components.

Tags: 
Posted: Oct 13,2026 by Roni Peleg